A signal from another clock domain can change right at your clock edge and leave the first flip-flop metastable. A second flip-flop gives it a full cycle to settle before any logic looks at it. Every CDC path starts with this circuit.

The module accepts an asynchronous input vector and passes it through two cascaded registers clocked by the destination domain clock. The first register captures the asynchronous input, and the second register captures the output of the first. This provides a stable synchronized output exactly two clock cycles after the input stabilizes.

Clocking is driven by clk on the positive edge. The module uses an asynchronous, active-low reset rst_n. On reset, all internal registers and the output evaluate to 0. No combinational logic is permitted between the asynchronous input and the first stage, nor between the first and second stages.

Cycle 1: rst_n=0 → stage1=0, sync_out=0
Cycle 2: rst_n=1, async_in=1 → stage1=0, sync_out=0 (input transitions)
Cycle 3: async_in=1 → stage1=1, sync_out=0 (stage1 captures input)
Cycle 4: async_in=1 → stage1=1, sync_out=1 (sync_out captures stage1)
Cycle 5: async_in=1 → stage1=1, sync_out=1 (steady state)
Cycle 6: async_in=0 → stage1=1, sync_out=1 (input transitions)
Cycle 7: async_in=0 → stage1=0, sync_out=1 (stage1 captures input)
Cycle 8: async_in=0 → stage1=0, sync_out=0 (sync_out captures stage1)

Signal Direction Width Description
clk input 1 Positive-edge triggered destination clock
rst_n input 1 Asynchronous active-low reset; all outputs and internal states go to 0 when asserted
async_in input WIDTH Asynchronous input data vector
sync_out output WIDTH Synchronized output data vector

Constraints

  • Parameter WIDTH must define the bit width of the input and output ports.
  • Reset must be asynchronous and active-low.
  • All output and internal register bits must evaluate to 0 on reset.
  • No combinational logic is allowed; the module must exclusively infer cascaded flip-flops.
  • The output sync_out must reflect the captured async_in exactly two clock cycles later.

Topics

Clock Domain CrossingRegistersSynchronizer

Solve this problem

Write the module in Verilog, SystemVerilog or VHDL. Your submission is compiled and simulated against the problem's testbench. You get the waveform back, not a stored answer.

Free to solve. A Codiode account keeps your progress.

The circuit builder and code editor need a desktop screen. On a phone, read the problem here and open it on a laptop to solve.

Part of Clock Domain Crossing and Synchronization

Problem 1 of 36 in the Clock Domain Crossing and Synchronization track.

Related problems

Browse all problems · Clock domain crossing (CDC) problems · Verilog practice problems · Learning tracks

Solve this on a laptopSend yourself the link and continue there.