Counter: Single Wrong Transition Diagnosis
A custom sequence counter controls the timing phases of a digital communication protocol. The counter must produce the continuous state sequence 3, 4, 5, 6, 7, repeating back to 3.
Expected behavior:
| Q2 | Q1 | Q0 | Next_Q2 | Next_Q1 | Next_Q0 | |------|------|------|-----------|-----------|-----------| | 0 | 1 | 1 | 1 | 0 | 0 | | 1 | 0 | 0 | 1 | 0 | 1 | | 1 | 0 | 1 | 1 | 1 | 0 | | 1 | 1 | 0 | 1 | 1 | 1 | | 1 | 1 | 1 | 0 | 1 | 1 |
Simulation shows the observed sequence is 3, 5, 4, 7, 6, 3. State 3 (011) incorrectly transitions to 5 (101). State 4 (100) incorrectly transitions to 7 (111).
Inspect the circuit and correct the fault.
Constraints
- Do not modify the clock or reset networks.
- Do not add additional flip-flops.
- Only replace or rewire the existing faulty logic gates.
Topics