Codiode

Mod-6 Counter: Self-Correction by Explicit Next-State Assignment

MediumLogic CircuitBuild

Mission-critical state machines cannot rely on undefined behavior for invalid states. The next-state logic for a fault-tolerant mod-6 counter must explicitly route any illegal state back to the reset state to prevent system lockup from single-event upsets.

The circuit computes the next state (D2, D1, D0) given the current state (Q2, Q1, Q0). The counter increments normally from 0 to 5. If the current state is 6 or 7, the next state must immediately evaluate to 0.

Q2 Q1 Q0 D2 D1 D0
0 0 0 0 0 1
0 0 1 0 1 0
0 1 0 0 1 1
0 1 1 1 0 0
1 0 0 1 0 1
1 0 1 0 0 0
1 1 0 0 0 0
1 1 1 0 0 0

Constraints

  • Implement combinational logic only.
  • Route states 6 and 7 explicitly to state 0.
  • Do not use sequential elements.

Topics

countersstate-machinesfault-tolerance

Solve this problem

Place the gates, wire them up and watch the signals settle. Every submission runs on the same simulation engine that grades it.

This problem is part of Codiode Pro. The statement above is free to read.

The circuit builder and code editor need a desktop screen. On a phone, read the problem here and open it on a laptop to solve.

Part of Counters

Problem 102 of 139 in the Counters track.

Related problems

Browse all problems · Digital logic design practice problems · Learning tracks