Codiode

Synchronous Counter Q3 Stuck-at-0 Debug

HardLogic CircuitDebug

A 4-bit synchronous up counter tracks clock pulses and increments its binary value on every active clock edge. The circuit should count from 0 to 15 and then wrap around to 0.

Expected behavior:

State Q3 Q2 Q1 Q0
0 0 0 0 0
1 0 0 0 1
2 0 0 1 0
3 0 0 1 1
4 0 1 0 0
5 0 1 0 1
6 0 1 1 0
7 0 1 1 1
8 1 0 0 0
... ... ... ... ...
15 1 1 1 1

Simulation shows the counter advancing from state 0 to state 7 correctly. On the next clock pulse, the circuit outputs Q3=0, Q2=0, Q1=0, Q0=0 instead of state 8. The Q3 output remains 0 for all states in an infinite cycle.

Inspect the circuit and correct the fault.

Constraints

  • Do not alter the clock distribution network.
  • Preserve the synchronous architecture: all flip-flops must be driven by the same clock signal.
  • Use only standard logic gates for the next-state logic.

Topics

debuggingsequential-logiccountersstuck-at-fault

Solve this problem

Place the gates, wire them up and watch the signals settle. Every submission runs on the same simulation engine that grades it.

This problem is part of Codiode Pro. The statement above is free to read.

The circuit builder and code editor need a desktop screen. On a phone, read the problem here and open it on a laptop to solve.

Part of Counters

Problem 19 of 139 in the Counters track.

Related problems

Browse all problems · Digital logic design practice problems · Learning tracks

Solve this on a laptopSend yourself the link and continue there.